P0500
System/ComponentVehicle Speed Interface
Fault Code
P0500
Fault Type
Plausibility Yes
Signal No
Minimum Threshold No
Maximum Threshold No
Monitoring Method
Plausibility
Signal Type
Pulsating rectangular wave on/off-cycles with constant or varying on/off-times
Operating Range
yes/no
Time Length and Frequency for Monitoring/Diagnosis
1 sec/permanent
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT No
Ground No
Disconnect No
Electronic Control Module (ECM)
Engine speed and engine load exceed limits (2400 min-1; 117.5 kg/h) and no vehicle speed signal present