P0600
ComponentEngine Control Module
Fault Code
P0600
Fault Type
Plausibility Yes
Signal No
Minimum Threshold No
Maximum Threshold No
Monitoring Method
CAN Bus Check
Signal Type
ECM internal signal/value computation or comparison
Operating Range
None
Time Length and Frequency for Monitoring/Diagnosis
Once per ignition key on
Criteria for storing fault code
Fault during two trips
Criteria for illuminating the MIL
Fault during two trips and end of second trip
Criteria used for determining out of range values and input component rationality check
UBATT No
Ground No
Disconnect No
Electronic Control Module (ECM) RAM and ROM Check