P0740
System/ComponentTorque Converter Clutch
Fault Code
P0740
Fault Type
Plausibility Yes
Signal No
Minimum Threshold No
Maximum Threshold No
Monitoring Method
Plausibility/check circuit
Signal Type
ECM internal signal/value computation or comparison
Time Length and Frequency for Monitoring/Diagnosis
25 sec/once per ignition key on
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT Yes
Ground Yes
Disconnect Yes
Electronic Control Module (ECM)
Fault if (engine speed - calculated turbine speed) is > 288 rpm.