P1525
System/ComponentVariable Camshaft Timing (VANOS) solenoid valve
Fault Code
P1525
Fault Type
Plausibility No
Signal Yes
Minimum Threshold Yes
Maximum Threshold Yes
Monitoring Method
Voltage/current range check
Signal Type
On/off switching signal
Operating Range
yes/no
Time Length and Frequency for Monitoring/Diagnosis
Once per revolution/permanent
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT Yes
Ground Yes
Disconnect Yes
Electronic Control Module (ECM)
U < 2.9V if output is not active
0.02 A < I < 2A if output is active