P1746
System/ComponentEGS Relay
Fault Code
P1746
Fault Type
Plausibility No
Signal Yes
Minimum Threshold No
Maximum Threshold No
Monitoring Method
Final stage check
Signal Type
non-pulsating signal
Time Length and Frequency for Monitoring/Diagnosis
25 sec/once per ignition key on
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT Yes
Ground Yes
Disconnect Yes
Electronic Control Module (ECM)
Circuit continuity check