Operation CHARM: Car repair manuals for everyone.

P0335










Electrical Diagram:






CIRCUIT DESCRIPTION

The Crankshaft Position Sensor CKP is mounted in the right rear of the engine block behind the starter. The CKP sensor works in conjunction with a 24X reluctor wheel mounted on the rear of the crankshaft. The CKP sensor has a B+ power supply, a ground, and a signal circuit.

As the crankshaft rotates, the reluctor wheel teeth interrupt a magnetic field produced by a magnet within the sensor. The sensor's internal circuitry detects this and produces a signal which the PCM reads. The PCM uses this signal to accurately measure crankshaft velocity which is a variable used in order to detect misfire, spark and, fueling.


CONDITIONS FOR SETTING THE DTC

^ DTCs P0101, P0102 , P0103, P0341, P0342, P0343 are not set.

^ Engine Speed is between 500 and 4000 RPM.

^ Ignition Voltage is between 9.0 and 17.0 volts.

^ MAF is greater than 3 g/s.

^ The PCM determines that the CKP sensor signal is out of range for less than 1 second.


ACTION TAKEN WHEN THE DTC SETS

^ The PCM illuminates the Malfunction Indicator Lamp (MIL) when the diagnostic runs and fails.

^ The PCM records the operating conditions at the time the diagnostic fails. The PCM stores this information in the Freeze Frame and/or the Failure Records.


CONDITIONS FOR CLEARING THE MIL/DTC

^ A History DTC clears after forty consecutive warm-up cycles, if this or any other emission related diagnostic does not report any failures.

^ The PCM battery voltage is interrupted.

^ Use a scan tool in order to clear the MIL/DTC.

DIAGNOSTIC AIDS

This DTC will not report a pass. The scan tool status for this DTC will never report a pass so it will appear that the diagnostic never runs. This will cause the MIL to remain ON until a DTC clear command or battery disconnect occurs.

The following problems may cause this DTC to set:

^ Poor connections/terminal tension at the sensor

^ Crankshaft reluctor wheel damage or improper installation

^ The sensor coming in contact with the reluctor wheel

^ The engine running out of fuel

Using Freeze Frame and/or Failure Records data may aid in locating an intermittent condition. If you cannot duplicate the DTC, the information included in the Freeze Frame and/or Failure Records data can aid in determining how many miles since the DTC set. The Fail Counter and Pass Counter can also aid determining how many ignition cycles the diagnostic reported a pass and/or a fail. Operate the vehicle within the same freeze frame conditions (RPM, load, vehicle speed, temperature etc.) that you observed. This will isolate when the DTC failed. For an intermittent condition, refer to Symptoms. Testing and Inspection

Excess crankshaft end play will cause the CKP sensor reluctor wheel to move out of alignment with the CKP sensor. This could result in any one of the following:

^ A no start

^ A start and stall

^ Erratic performance

An improperly installed propeller shaft could cause excess crankshaft end play. Refer to Engine Mechanical for excess crankshaft end play diagnosis. For an intermittent, refer to Symptoms. Testing and Inspection

TEST DESCRIPTION

The numbers below refer to the step numbers on the diagnostic table.

3. This step determines if the fault is present.

6. This step simulates a CKP sensor signal to the PCM. If the PCM receives the signal, the fuel pump will operate for about two seconds. If the fuel pump operates, the problem is either terminal contact at the CKP sensor, the CKP sensor or, the CKP sensor reluctor wheel.

7. This test determines if the CKP sensor signal circuit or if the PCM is faulty.

12. To inspect the reluctor wheel, remove the starter and rotate the crankshaft while viewing the reluctor wheel through the CKP sensor hole. It you cannot determine if the reluctor wheel is damaged, the oil pan may have to be removed.

15. Before replacing the PCM, check the PCM harness connections.

16. This DTC will not report a pass. The scan tool status for this DTC will never report a pass. The scan tool will only display when the diagnostic fails. The repair is not complete if the scan tool indicates that the diagnostic ran and failed.