Instrument Panel Cluster (IPC) - Replacement
Instrument Cluster Replacement
Removal Procedure
Important: The ignition switch must be in the OFF position when removing the instrument cluster assembly.
1. Remove the IP cluster trim plate. Refer to Instrument Cluster Trim Panel Replacement (Standard Column) (Instrument Cluster Trim Panel Replacement (Standard Column))Instrument Cluster Trim Panel Replacement (Tilt Column) (Instrument Cluster Trim Panel Replacement (Tilt Column)) .
2. Remove the 3 screws which secure the instrument cluster assembly.
3. Disconnect the 4 electrical connectors (2) from the cluster assembly (1).
4. Remove the cluster assembly (1) from the instrument panel assembly.
Installation Procedure
1. Connect the 4 electrical connectors (2) to the instrument cluster assembly (1).
2. Install the cluster assembly to the instrument panel assembly. Secure the assembly with the 3 screws.
3. Install the IP cluster trim plate. Refer to Instrument Cluster Trim Panel Replacement (Standard Column) (Instrument Cluster Trim Panel Replacement (Standard Column))Instrument Cluster Trim Panel Replacement (Tilt Column) (Instrument Cluster Trim Panel Replacement (Tilt Column)) .