P1637
Diagnostic Chart (Part 1 Of 2):
Diagnostic Chart (Part 2 Of 2):
Schematic:
CIRCUIT DESCRIPTION
The L-terminal circuit from the generator is a discrete circuit into the Powertrain Control Module (PCM). The PCM supplies the ignition voltage to the generator lamp feed. This ignition voltage is pulled low by the generator once the ignition switch supplies ignition 1 voltage. The voltage stays low until the generator turns. When the generator is up and running, the PCM detects ignition voltage. Therefore, with no failures with the vehicles charging system, the lamp terminal circuit will go low 0 volts when the ignition switch is powered up and then goes to the ignition voltage after the engine is started.
When the charging system detects a fault such as a circuit shorted to ground, the Instrument Panel Cluster (IPC) displays a message.
CONDITIONS FOR RUNNING THE DTC
Engine operating
CONDITIONS FOR SETTING THE DTC
The PCM detects an improper voltage on the generator L- terminal circuit.
ACTION TAKEN WHEN THE DTC SETS
^ The PCM stores the DTC information into memory when the diagnostic runs and fails.
^ The Malfunction Indicator Lamp (MIL) will not illuminate.
^ The PCM records the operating conditions at the time the diagnostic fails. The PCM stores this information in the Failure Records.
CONDITIONS FOR CLEARING THE DTC
^ A last test failed, or current DTC, clears when the diagnostic runs and does not fail.
^ A history DTC will clear after 40 consecutive warm-up cycles, if no failures are reported by this or any other non-emission related diagnostic.
^ Use a scan tool in order to clear the DTC.
DIAGNOSTIC AIDS
IMPORTANT: Remove any debris from the PCM connector surfaces before servicing the PCM. Inspect the PCM connector gaskets when diagnosing or replacing the PCM. Ensure that the gaskets are installed correctly. The gaskets prevent water intrusion into the PCM.
^ The following may cause an intermittent:
- Poor connections - Check for adequate terminal tension. Refer to Testing for Intermittent and Poor Connections in Diagrams.
- Corrosion
- Mis-routed harness
- Rubbed through wire insulation
- Broken wire inside the insulation
^ For an intermittent, refer to Symptoms. Symptom Related Diagnostic Procedures
^ A generator fault, such as a shorted output diode, malfunctioning regulator, open or shorted rotor may cause a low battery charge. Refer to A Diagnostic System Check - Starting and Charging in Starting and Charging for further information and generator diagnosis. Testing and Inspection
^ Use a scan tool in order to diagnosis the generator circuits. A scan tool displays Generator L-Terminal Inactive when there is a problem with the L-terminal circuit.
TEST DESCRIPTION
The numbers below refer to the step numbers on the Diagnostic Table.
2. This step determines if a fault is present.
11. A poor connection at the generator causes no output.