P0403



DTC P0403

CIRCUIT DESCRIPTION
The exhaust gas recirculation (EGR) valve is controlled by the engine control module (ECM) through the EGR motor high control and the EGR motor low control circuits. The ECM supplies voltage that is near ignition voltage to the high and low control circuits at all times. The ECM will pulse width modulation (PWM) the low control circuit to ground when EGR is desired. The lower the pulse width, the more the valve will open. The ECM will PWM the high control circuit to ground when the EGR valve is desired closed. If the ECM detects an electrical malfunction on the control circuits, DTC P0403 will set.

DTC DESCRIPTOR
This diagnostic procedure supports the following DTC:
DTC P0403 Exhaust Gas Recirculation (EGR) Solenoid Control Circuit

CONDITIONS FOR RUNNING THE DTC
- The engine is running for more than 0.5 seconds.
- The ignition voltage is between 11-18 volts.
- The intake air temperature (IAT) is between 0-150.75°C (32-303.35°F).
- The engine coolant temperature (ECT) is between 57-99.75°C (134.6-211.6°F).
- The barometric pressure (BARO) is more than 72 kPa.
- The EGR valve is commanded open.
- DTC P0403 runs continuously once the above conditions are met.

CONDITIONS FOR SETTING THE DTC
- The ECM detects an electrical malfunction on an EGR motor control circuit.
- The above condition is present for more than 10 seconds.

ACTION TAKEN WHEN THE DTC SETS - CALIFORNIA
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

ACTION TAKEN WHEN THE DTC SETS - FEDERAL
- The control module stores the DTC information into memory when the diagnostic runs and fails.
- The MIL will not illuminate.
- The control module records the operating conditions at the time the diagnostic fails. The control module stores this information in the Failure Records.
- The driver information center (DIC), if equipped, may display a message.

CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.

TEST

Steps 1-11: