Low Fuel Indicator Inoperative
Low Fuel Indicator Inoperative
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.
Circuit Description
The engine control module (ECM) monitors the signal circuit of the fuel level sender in order to determine fuel level. The sender consists of a variable resistor that changes resistance based on the fuel level in the tank. The ECM monitors the voltage across the sender resistance in order to determine the fuel level. The ECM uses the signal circuit of the fuel level sender in order to calculate the total remaining fuel, in percent. The ECM sends the fuel level percent via the serial data circuit to the instrument cluster (IPC) in order to control the fuel gage. When the fuel level percent reaches a predetermined low level, the IPC will illuminate the low fuel indicator.
Reference Information
Schematic Reference
Instrument Cluster Schematics (Instrument Cluster Schematics)
Connector End View Reference
Component Connector End Views (Connector Views)
Description and Operation
Instrument Cluster Description and Operation (Description and Operation)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
Scan Tool Reference
Control Module References (Programming and Relearning)
Circuit/System Testing
1. Ignition ON, perform the lamp test with the scan tool.
2. If the low fuel indicator does not illuminate, replace the IPC.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
Control Module References (Programming and Relearning) for the IPC replacement, setup, and programming