Test Q: The Reversing Lamps Are Inoperative
PINPOINT TEST Q: THE REVERSING LAMPS ARE INOPERATIVEQ1-Q2:
Q2-Q4:
Q4-Q7:
Q7 Continued:
Normal Operation - Manual Transaxle
The central junction box (CJB) provides voltage to the reversing lamp switch through circuit 15-LG28 (GN/WH). When the transaxle is placed in REVERSE, voltage is routed to the reversing lamps through circuit 15S-LG3 (GN/YE).
Normal Operation - Automatic Transaxle
When the transaxle is placed in REVERSE, voltage is routed to the CJB fuse 40 (10A) through circuit 15S-TA38B (GN/BU). The voltage is then routed to the reversing lamps through circuit 15S-LG9 (GN/BK).
Possible Causes
- Fuse
- Circuit 15-LG28 (GN/WH) open
- Circuit 15S-LG3 (GN/YE) open
- Circuit 15S-TA38B (GN/BU) open
- Circuit 15S-LG9 (GN/BK) open
- Reversing lamp switch
- CJB