Test L: One Turn Signal/Hazard Lamp Is Inoperative
PINPOINT TEST L: ONE TURN SIGNAL/HAZARD LAMP IS INOPERATIVEL1-L2:
L2-L3:
L4:
Normal Operation
When the multifunction switch is placed in the LH or RH TURN position, the generic electronic module (GEM) then provides voltage to circuits 49S-LG5 (BU/WH) and 49S-LG4 (BU/RD) to the LH and RH front turn lamps, respectively. Ground is provided on circuits 31-LG11 (BK) and 31-LG18 (BK) for the LH and RH front turn lamps, respectively.
Possible Causes
- Circuit 31-LG11 (BK) open
- Circuit 31-LG18 (BK) open
- Circuit 49S-LG4 (BU/RD) open or short to ground
- Circuit 49S-LG5 (BU/WH) open or short to ground
- Circuit 49S-LG11 (BU/OG) open or short to ground
- Circuit 49S-LG13 (BU/RD) short to ground
- Circuit 49S-LG18 (BU) open or short to ground
- Circuit 49S-LG20 (BU/WH) short to ground
- GEM