P0448
TROUBLESHOOTING PROCEDURES
Circuit Diagram: Leak Detection Valve-[Canister Close Valve (CCV)]:
CIRCUIT DIAGRAM
HARNESS INSPECTION PROCEDURES
COMPONENT INSPECTION
Canister Close Valve (CCV)-Operational Inspection
1. Connect the CCV pins to a wire as shown.
2. At idle, disconnect the CCV connector.
3. Inspect that CCV is close when attaching the wire to (-) of battery.
4. Inspect that CCV is open when detaching the wire from (-) of battery.
NOTE: Use a very thin paper and attach it to the hose on CCV and observe the CCV operation/condition.
1) If the paper is absorbed into or out, CCV is open.
2) If not, CCV is closed.