P0562
TROUBLESHOOTING PROCEDURES
1. Verify battery condition and state of charge. Correct as needed.
2. Verify charging system is operating properly, not over or under charging. Correct as needed.
3. If Battery and Charging System check OK, proceed with Main Relay test below.
CIRCUIT DIAGRAM
HARNESS INSPECTION PROCEDURES
RELAY INSPECTION
1. Check for continuity of relay coil windings between terminal 4 (+) and 2 (-).
2. Check continuity of relay contacts between terminals 5 and 1.
3. Check continuity of relay contacts between terminals 5 and 3.
4. If faulty, replace the MFI control relay.
Tightening torque: MFI control relay 7-11 Nm (7-110 kg.cm, 5.2-8.1 lb.ft.)
TROUBLESHOOTING HINTS