P0562
P0562 - SYSTEM VOLTAGE LOWCIRCUIT DIAGRAM
TROUBLESHOOTING PROCEDURES
1. Verify battery condition and state of charge. Correct as needed.
2. Verify charging system is operating properly, not over or under charging. Correct as needed.
3. If Battery and Charging System check OK, proceed with Main Relay test below.
MFI CONTROL RELAY INSPECTION
Part 1 Of 4:
Part 2 Of 4:
1. Check continuity of relay contacts between terminal 4 (+) and 2 (-).
2. If faulty, replace the MFI control relay.
Tightening torque
MFI control relay 7 - 11 Nm (7 - 110 kg.cm, 5.2 - 8.1 lb.ft)
HARNESS INSPECTION PROCEDURE