P0710
DescriptionThe A/T fluid temperature sensor detects the A/T fluid temperature and sends a signal to the TCM.
CONSULT REFERENCE VALUE IN DATA MONITOR MODE
Remarks: Specification data are reference values.
TCM TERMINALS AND REFERENCE VALUE
Remarks: Specification data are reference values.
ON BOARD DIAGNOSIS LOGIC
DIAGNOSTIC TROUBLE CODE (DTC) CONFIRMATION PROCEDURE
CAUTION: Always drive vehicle at a safe speed.
NOTE: If "DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE" has been previously conducted, always turn ignition switch "OFF" and wait at least 5 seconds before conducting the next test.
After the repair, perform the following procedure to confirm the malfunction is eliminated.
With CONSULT
1) Turn ignition switch "ON" and select "DATA MONITOR" mode for "ENGINE" with CONSULT.
2) Start engine and maintain the following conditions for at least 10 minutes (Total). (it is not necessary to maintain continuously.)
CMPS-RPM (REF): 450 rpm or more
VHCL SPEED SE: 10 km/h (6 MPH) or more
THRTL POS SEN: More than 1.2 V
Selector lever: D position (OD "ON")
With GST
Follow the procedure "With CONSULT".
Wiring Diagram - AT - FTS
Diagnostic Procedure
Part 1 of 4
Part 2 of 4
Part 3 of 4
Part 4 of 4
Component Inspection
A/T FLUID TEMPERATURE SENSOR
- Check resistance between terminals 8 and 9 while changing temperature as shown at left.