Ignition Relay: Testing and Inspection
Relay:
Check continuity between terminals
(3)
and
(5)
.
Conditions
Continuity
12 Volts (fused) direct current
Yes
supply between terminals
(1)
and
(2)
No current supply
No
If Not Good, replace relay.