Operation CHARM: Car repair manuals for everyone.

Code 1008




DESCRIPTION

SYSTEM DESCRIPTION
This system controls flow rate of fuel vapor from the EVAP canister. The opening of the vapor bypass passage in the EVAP canister purge volume control valve changes to control the flow rate. A built-in step motor moves the valve in steps corresponding to the ECM output pulses. The opening of the valve varies for optimum engine control. The optimum value stored in the ECM is determined by considering various engine conditions. When the engine is operating, the flow rate of fuel vapor from the EVAP canister is regulated as the air flow changes.




COMPONENT DESCRIPTION
The EVAP canister purge volume control valve uses a step motor to control the flow rate of fuel vapor from the EVAP canister. This motor has four winding phases. It operates according to the output pulse signal of the ECM. Two windings are turned ON and OFF in sequence. Each time an ON pulse is issued, the valve opens or closes, changing the flow rate. When no change in the flow rate is needed, the ECM does not issue the pulse signal. A certain voltage signal is issued so that the valve remains at that particular opening.




CONSULT Reference Value in Data Monitor Mode




ECM Terminals and Reference Value
Specification data are reference values and are measured between each terminal and 43 (ECM ground).




ON BOARD DIAGNOSIS LOGIC

DTC CONFIRMATION PROCEDURE

NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 5 seconds before conducting the next test.

TESTING CONDITION: Before performing the following procedure, confirm battery voltage is more than 11 V with ignition switch "ON".




With CONSULT
1. Turn ignition switch "ON".
2. Select "DATA MONITOR" mode with CONSULT.
3. Wait at least 5 seconds.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure".

With GST
1. Turn ignition switch "ON" and wait at least 5 seconds.
2. Select "MODE 7" with GST.
3. If 1st trip DTC is detected, go to "Diagnostic Procedure".

Without Scan Tools
1. Turn ignition switch "ON" and wait at least 5 seconds.
2. Turn ignition switch "OFF", wait at least 5 seconds and then turn "ON".
3. Perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure".







WIRING DIAGRAM

1 CHECK POWER SUPPLY:




2 DETECT MALFUNCTIONING PART:




3 CHECK OUTPUT SIGNAL CIRCUIT:




4 CHECK EVAP CANISTER PURGE VOLUME CONTROL VALVE:




5 CHECK INTERMITTENT INCIDENT:




DIAGNOSTIC PROCEDURE

COMPONENT INSPECTION

EVAP CANISTER PURGE VOLUME CONTROL VALVE










With CONSULT
1. Disconnect EVAP canister purge volume control valve harness connector.
2. Check resistance between the following terminals.
terminal 2 and terminals 1,3
terminal 5 and terminals 4,6
Resistance: 35 - 43 Ohms [At 20 °C (68 °F)]
If NG, replace the EVAP canister purge volume control valve.
If OK, go to the following step.
3. Reconnect EVAP canister purge volume control valve harness connector.
4. Remove EVAP canister purge volume control valve from intake manifold collector and disconnect hoses from the valve. (Plug the purge hoses. The EVAP canister purge volume control valve harness connector should remain connected.)
5. Turn ignition switch "ON".
6. Perform "PURG VOL CONT/V" in "ACTIVE TEST" mode with CONSULT Check that EVAP canister purge volume control valve shaft moves smoothly forward and backward according to the valve opening.
If NG, replace the EVAP canister purge volume control valve.

Without CONSULT
1. Disconnect EVAP canister purge volume control valve harness connector.
2. Check resistance between the following terminals.
terminal 2 and terminals 1,3
terminal 5 and terminals 4, 6
Resistance: 35 - 43 Ohms [At 20 °C (68 °F)]
If NG, replace the EVAP canister purge volume control valve.
If OK, go to the following step.
3. Reconnect EVAP canister purge volume control valve harness connector.
4. Remove EVAP canister purge volume control valve from intake manifold collector and disconnect hoses from the valve. (Plug the purge hoses. The EVAP canister purge volume control valve harness connector should remain connected.)
5. Turn ignition switch "ON" and "OFF". Check that EVAP canister purge volume control valve shaft moves smoothly forward and backward according to the ignition switch position.
If NG, replace the EVAP canister purge volume control valve.