Operation CHARM: Car repair manuals for everyone.

P0135

System Description:




System Description
The ECM performs ON/OFF control of the heated oxygen sensor 1 heater (Front) corresponding to the engine operation condition.

Operation:






Consult-II Reference Value In Data Monitor Mode:






ECM Terminals And Reference Value:






On Board Diagnosis Logic:






DTC Confirmation Procedure

NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 10 seconds before conducting the next test.

TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10.5 V and 16 V at idle.

With CONSULT-II
1. Turn ignition switch "ON" and select "DATA MONITOR" mode with CONSULT-II.
2. Start engine and run it for at least 6 seconds at idle speed.
3. If 1st trip DTC is detected, go to "Diagnostic Procedure".

With GST
1. Start engine and run it for at least 6 seconds at idle speed.




2. Turn ignition switch "OFF" and wait at least 10 seconds.
3. Start engine and run it for at least 6 seconds at idle speed.
4. Select "MODE 3" with GST.
5. If DTC is detected, go to "Diagnostic Procedure".
- When using GST, "DTC Confirmation Procedure" should be performed twice as much as when using CONSULT-II because GST cannot display MODE 7 (1st trip DTC) concerning this diagnosis. Therefore, using CONSULT-II is recommended.

EC-HO2S1H-01:




EC-HO2S1H-01 Connector View:




Wiring Diagram

Fuse Block - Junction Box (J/B) Terminal Arrangement (B1, E71, E72, E73, M1, M2, M3, M4, M5):






Steps 1 - 3:




Steps 4 - 5:




Diagnostic Procedure

Component Inspection




HEATED OXYGEN SENSOR 1 HEATER (FRONT)
Check resistance between terminals 3 and 1.
Resistance: 2.3 - 4.3 at 25 °C (77 °F)

Check continuity between terminals 2 and 1, 3 and 2.
Continuity should not exist.

If NG, replace the heated oxygen sensor 1 (front).

CAUTION:
- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.