P0710
Description1 of 2
2 of 2
The A/T fluid temperature sensor detects the A/T fluid temperature and sends a signal to the TCM.
CONSULT-II REFERENCE VALUE IN DATA MONITOR MODE
TCM TERMINALS AND REFERENCE VALUE
ON BOARD DIAGNOSIS LOGIC
DIAGNOSTIC TROUBLE CODE (DTC) CONFIRMATION PROCEDURE
CAUTION: Always drive vehicle at a safe speed.
NOTE: If "DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE" has been previously conducted, always turn ignition switch "OFF" and wait at least 5 seconds before conducting the next test.
After the repair, perform the following procedure to confirm the malfunction is eliminated.
With CONSULT-II
1. Turn ignition switch "ON" and select "DATA MONITOR" mode for "ENGINE" with CONSULT-II.
2. Start engine and maintain the following conditions for at least 10 minutes (Total). (it is not necessary to maintain continuously.)
CMPS-RPM (REF): 450 rpm or more
VHCL SPEED SE: 10 km/h (6 MPH) or more
THRTL POS SEN: More than 1.2 V
Selector lever: D position (OD "ON")
With GST
Follow the procedure "With CONSULT-II".
Wiring Diagram - AT - FTS
Diagnostic Procedure
1 of 5
2 of 5
3 of 5
4 of 5
5 of 5
A/T FLUID TEMPERATURE SENSOR
- Check resistance between two terminals while changing temperature as shown.