P1136
DTC P1136 IVT CONTROL SOLENOID VALVEComponent Description
Intake valve timing control solenoid valve is activated by ON/OFF pulse duty (ratio) signals from the ECM.
The intake valve timing control solenoid valve changes the oil amount and direction of flow through intake valve timing control unit or stops oil flow.
The longer pulse width advances valve angle.
The shorter pulse width retards valve angle.
When ON and OFF pulse widths become equal, the solenoid valve stops oil pressure flow to fix the intake valve angle at the control position.
Consult-II Reference Value In Data Monitor Mode:
On Board Diagnosis Logic:
DTC Confirmation Procedure
NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11 V at idle.
WITH CONSULT-II
1. Turn ignition switch "ON".
2. Select "DATA MONITOR" mode with CONSULT-II.
3. Maintain the specified conditions for at least 5 seconds.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure".
WITH GST
Following the procedure "With CONSULT-II".
EC-IVCB1-01:
EC-IVCB2-01:
Wiring Diagram
Diagnostic Procedure Step 1:
Diagnostic Procedure Step 2 - 5:
Diagnostic Procedure
Component Inspection
INTAKE VALVE TIMING CONTROL SOLENOID VALVE
1. Disconnect intake valve timing control solenoid valve harness connector.
2. Check resistance between intake valve timing control solenoid valve terminals as shown.
Removal and Installation
INTAKE VALVE TIMING CONTROL SOLENOID VALVE
Refer to "TIMING CHAIN".