Operation CHARM: Car repair manuals for everyone.

Without Scan Tool

Self-diagnosis Function




DESCRIPTION
The self-diagnosis system diagnoses sensors, door motors, blower motor, etc. by system line. Refer to applicable sections (items) for details. Shifting from usual control to the self-diagnosis system is accomplished by starting the engine (turning the ignition switch ON) and pressing OFF switch for at least 5 seconds. The OFF switch must be pressed within 10 seconds after starting the engine (ignition switch is turned ON). This system will be canceled by either pressing AUTO.ECON switch or turning the ignition switch OFF. Shifting from one step to another is accomplished by means of turning Temperature control dial, as required.

Additionally shifting from STEP-5 to AUXILIARY MECHANISM is accomplished by means of pushing (fan) UP switch.

Function Confirmation Procedure (Steps 1 - 4):




Function Confirmation Procedure (Steps 5 - 7):




Function Confirmation Procedure (Steps 8 - 9):




Function Confirmation Procedure (Steps 10 - 13):




Function Confirmation Procedure (Step 14):




Function Confirmation Procedure (Step 15):




FUNCTION CONFIRMATION PROCEDURE




AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER
The trimmer compensates for differences in range of ± 3 degrees C (± 6 degrees F) between temperature setting (displayed digitally) and temperature felt by customer.

Operating procedures for this trimmer are as follows:
1. Begin self-diagnosis STEP-5 mode. Refer to "Self-diagnosis Function".
2. Press (fan) UP switch to set system in auxiliary mode.
3. Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
4. Turn temperature control dial as desired. Temperature will change at a rate of 0.5 degrees C (1.0 degree F) each time a dial is turned.

When battery cable is disconnected, trimmer operation is canceled. Temperature set becomes that of initial condition, i.e. 0 degrees C (0 degrees F).




AUXILIARY MECHANISM: FOOT POSITION SETTING TRIMMER
Wind distribution ratio in FOOT mode can be set.
Operating procedures for this trimmer are as follows:
1. Begin self-diagnosis STEP-5 mode. Refer to "Self-diagnosis Function".
2. Press (fan) UP switch to set system in auxiliary mode.
3. Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
4. Press the mode switch as desired.




AUXILIARY MECHANISM: INLET PORT MEMORY FUNCTION
When ignition switch is turned from OFF to ON, inlet port can be set to AUTO or manual.

Operating procedures for this trimmer are as follows:
1. Begin self-diagnosis STEP-5 mode. Refer to "Self-diagnosis Function".
2. Press (fan) UP switch to set system in auxiliary mode.
3. Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
4. Press the recirculation (REC) and fresh (FRE) switch as desired.