Operation CHARM: Car repair manuals for everyone.

P2759

DTC P2759 TORQUE CONVERTER CLUTCH PRESSURE CONTROL SOLENOID CONTROL CIRCUIT ELECTRICAL(SHIFT SOLENOID VALVE SLU)

CIRCUIT DESCRIPTION

DTC Detection Condition:




The amount of current flow to the solenoid is controlled by the
(*) duty ratio of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.




DTC Detection Condition:




(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then

(*) Duty Ratio = A/A + B � 100 (%)

MONITOR DESCRIPTION

Monitor Strategy:




Typical Enabling Conditions:




Typical Malfunction Thresholds:




Component Operating Range:




The ECM controls the oil pressure to the lock-up clutch based on engine-load information from the throttle position sensor, crankshaft position sensor, input speed sensor, and the oil pressure sensor for shift-solenoid SLU. The ECM commands the shift-solenoid SLU using a duty-cycle control signal. In turn, the shift solenoid operates the lock-up control valve and cause lock-up or flexible lock-up of the torque converter clutch. The ECM illuminates the MIL and store the DTC when ECM detects an open or a short circuit malfunction in the shift solenoid valve SLU.

Wiring Diagram:






Step 1 - 2:




Step 3:




INSPECTION PROCEDURE