Operation CHARM: Car repair manuals for everyone.

P0985









AB60F AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: P0985: Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)

DTC P0985 - Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)

DTC P0986 - Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)

DESCRIPTION

Shifting from 1st to 6th is performed in combination with the ON and OFF operation of shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely. Also, the ECM stops sending current to the open or short circuited shift solenoid valve Fail-Safe Chart.






MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve SR is ON, if its resistance is 8 Ohms or less, the ECM determines there is a short in the shift solenoid valve SR circuit.
When shift solenoid valve SR is OFF, if its resistance is 100 kOhms or higher, the ECM determines there is an open in the shift solenoid valve SR circuit Fail-Safe Chart.

MONITOR STRATEGY





TYPICAL ENABLING CONDITIONS

All





P0985: Range Check (Low Resistance)





P0986: Range Check (High Resistance)





TYPICAL MALFUNCTION THRESHOLDS

P0985: Range Check (Low Resistance)





P0986: Range Check (High Resistance)





COMPONENT OPERATING RANGE





WIRING DIAGRAM





INSPECTION PROCEDURE
HINT:
Shift solenoid valve SR is turned ON/OFF normally when the shift lever is in D:





PROCEDURE

1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)





(a) Disconnect the C39 No. 1 transmission wire connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:






NG -- INSPECT SHIFT SOLENOID VALVE SR
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)





(a) Disconnect the C53 ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:






NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ECM
3. INSPECT SHIFT SOLENOID VALVE SR





(a) Remove shift solenoid valve SR.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:





(c) Apply battery voltage (12 V) to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK:






NG -- REPLACE SHIFT SOLENOID VALVE SR
OK -- REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE