B1412
AIR CONDITIONING SYSTEM: B1412/12: Ambient Temperature Sensor Circuit
DTC B1412/12 - Ambient Temperature Sensor Circuit
DESCRIPTION
The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioner "AUTO" mode. This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT AIR CONDITIONING AMPLIFIER
(a) Connect the intelligent tester to the DLC3.
(b) Turn the ignition switch to the ON position and turn the intelligent tester main switch on.
(c) Select the item below in the DATA LIST, and read the display on the intelligent tester.
DATA LIST / AIR CONDITIONER:
OK:
The display is as specified in the normal condition column.
Result:
C -- REPLACE AIR CONDITIONING AMPLIFIER
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
A -- Continue to next step.
2. INSPECT AIR CONDITIONING AMPLIFIER
(a) Remove the A/C amplifier with connectors still connected.
(b) Turn the ignition switch to the ON position.
(c) Measure the voltage according to the value(s) in the table below.
Standard voltage:
HINT: As the temperature increases, the voltage decreases.
Result:
C -- REPLACE AIR CONDITIONING AMPLIFIER
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
A -- Continue to next step.
3. INSPECT A/C AMBIENT TEMPERATURE SENSOR
(a) Remove the A/C ambient temperature sensor.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPLACE A/C AMBIENT TEMPERATURE SENSOR
OK -- Continue to next step.
4. CHECK HARNESS AND CONNECTOR (A/C AMPLIFIER - A/C AMBIENT TEMPERATURE SENSOR)
(a) Disconnect the connector from the A/C ambient temperature sensor.
(b) Disconnect the connector from the A/C amplifier.
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE AIR CONDITIONING AMPLIFIER