B1432
AIR CONDITIONING SYSTEM: B1432/32: Air Inlet Damper Position Sensor Circuit
DTC B1432/32 - Air Inlet Damper Position Sensor Circuit
DESCRIPTION
This sensor detects the position of the air inlet control servo motor and sends the appropriate signals to the A/C amplifier assembly. The position sensor is built in the air inlet control servo motor.
The position sensor's resistance changes as the air inlet control servo motor arm moves.
It outputs voltage (5 V) that is input to terminal 1 (VZ) and terminal 3 (PT) via the variable resister, and then to the A/C amplifier assembly.
The A/C amplifier reads the arm position with the input voltage from the position sensor.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE OF TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch ON and push the Techstream main switch on.
(c) Select the item below in the DATA LIST, and read the display on the Techstream.
Air Conditioner
OK:
The display is as specified in the normal condition.
Result:
C -- REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
A -- Continue to next step.
2. INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
(a) Remove the A/C amplifier assembly with the connectors still connected.
(b) Change the set REC/FRS to activate the air inlet control servo motor.
(c) Measure the voltage according to the value(s) in the table below.
Voltage:
HINT: As the air inlet control servo motor is moved from REC side to FRS side, the voltage decreases gradually without interruption.
Result:
C -- REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
A -- Continue to next step.
3. INSPECT AIR INLET CONTROL SERVO MOTOR
(a) Remove the air inlet control servo motor.
(b) Disconnect the connector from the air inlet control servo motor.
(c) Measure the resistance according to the value(s) in the table below.
Resistance:
(d) Measure the resistance according to the value(s) in the table below.
Resistance:
(e) As the air inlet control servo motor moves from fresh to recirculation, the resistance decreases gradually without interruption.
HINT: For details regarding operation of the servo motor B1442.
NG -- REPLACE AIR INLET CONTROL SERVO MOTOR
OK -- Continue to next step.
4. CHECK HARNESS AND CONNECTOR (AIR INLET CONTROL SERVO MOTOR - A/C AMPLIFIER ASSEMBLY)
(a) Disconnect the connector from the A/C amplifier assembly.
(b) Measure the resistance according to the value(s) in the table below.
Resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY