P2759
AB60F AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
P2759 - Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
DESCRIPTION
The amount of current flow to the solenoid is controlled by the ECM. During the lock-up operation, if the current increases, the lock-up hydraulic pressure increases.
Reference: Inspect using an oscilloscope.
Check the waveform of the ECM connector.
Standard:
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store this DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Perform the universal trip to clear permanent DTCs Reading and Clearing Diagnostic Trouble Codes.
PROCEDURE
1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
(a) Disconnect the C39 No. 1 transmission wire connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- INSPECT SHIFT SOLENOID VALVE SLU
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
(a) Disconnect the C53 ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ECM Removal
3. INSPECT SHIFT SOLENOID VALVE SLU
(a) Remove shift solenoid valve SLU.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
(c) Apply battery voltage (12 V) to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK:
NG -- REPLACE SHIFT SOLENOID VALVE SLU Disassembly
OK -- REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE Removal