Operation CHARM: Car repair manuals for everyone.

Operating Light Control Rheostat Does Not Change Light Brightness





METER: METER / GAUGE SYSTEM: Operating Light Control Rheostat does not Change Light Brightness
- Operating Light Control Rheostat does not Change Light Brightness

DESCRIPTION

The combination meter receives signals for adjusting illumination on the meter of this circuit. The combination meter ECU detects the illumination level selected by the user according to the switch operation.

HINT
The meter illumination level can be adjusted by pushing the rheostat UP and DOWN switches.

WIRING DIAGRAM





INSPECTION PROCEDURE

PROCEDURE

1. READ VALUE USING TECHSTREAM (LIGHT CONTROL RHEOSTAT)

(a) Operate the Techstream according to the display and select "Data List".

Combination Meter:





OK:

Switch condition (ON/OFF) can be switched by actual operation.

NG -- INSPECT LIGHT CONTROL RHEOSTAT

OK -- REPLACE COMBINATION METER ASSEMBLY Disassembly

2. INSPECT LIGHT CONTROL RHEOSTAT





(a) Remove the rheostat Removal.

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:





NG -- REPLACE LIGHT CONTROL RHEOSTAT Removal
OK -- Continue to next step.

3. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT AND BODY GROUND)





(a) Disconnect the L10 meter connector.

(b) Disconnect the L8 rheostat connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard resistance:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR

OK -- REPLACE COMBINATION METER ASSEMBLY Disassembly