P0444
[4] Y58/1 (Purge control valve): Open circuit in wiring [P0444]
Check component Y58/1 (Purge control valve)
Test 1: Test actuation of component Y58/1 (Purge control valve)
Test 2: Test current consumption of component Y58/1 (Purge control valve)
Test 3: Perform mechanical inspection of component Y58/1 (Purge control valve)
1 Test actuation of component Y58/1 (Purge control valve)
Communication with ECU required.
2 Test current consumption of component Y58/1 (Purge control valve)
Test prerequisite
- Actuation is not okay.
Test sequence
- Switch off ignition.
- Connect socket box.
- [F.4] 100<-->16 [F.46]
- Switch on ignition
Specified value
- Amperage [0.3...0.5] A
Question: Is the measured value okay?
No
- The measured value is not o.k.
Possible cause and remedy
- Y58/1 (Purge control valve)
Yes
- The measured value is o.k.
Further possible causes of fault
- Perform mechanical inspection of component Y58/1 (Purge control valve).
3 Perform mechanical inspection of component Y58/1 (Purge control valve)
Figure legend
- 019 Vacuum tester
- Y58/1 (Purge control valve)
Test prerequisite
- Actuation is o.k.
Test sequence
- Switch off ignition.
- Connect the vacuum tester to the input of component Y58/1 (Purge control valve) with the 3 x distributor.
- Operate engine at idling speed.
- Engine at operating temperature
- Actuate component Y58/1 (Purge control valve), then with key F2.
Specified value
- Component Y58/1 (Purge control valve) should pulse.
- The value should be > 5 mbar during actuation.The pointer of the vacuum tester swings.
Communication with ECU required.