P0116
[8] B11/4 (Coolant temperature sensor): Signal IMPLAUSIBLE [P0116]
Check component B11/4 (Coolant temperature sensor).
Test 1: Check actual value B11/4 (Coolant temperature sensor).
Test 2: Test signal voltage of component B11/4 (Coolant temperature sensor).
Test 3: Test internal resistance of component B11/4 (Coolant temperature sensor).
1 Check actual value B11/4 (Coolant temperature sensor).
Note If fault exists, vehicle continues operating with substitute value from the temperature model.
Test prerequisite
- Run engine.
Status of relevant actual value:
- Temperature of coolant: Communication with ECU required
Specified value
- Actual value must change accordingly.
Question: Is the actual value o.k.?
2 Test signal voltage of component B11/4 (Coolant temperature sensor).
Test prerequisite
- The actual value is not o.k.
Test sequence
- Switch off ignition.
- Connect socket box (36 und 126-pin) to component N3/10 (ME-SFI control module).
- Connect adapter cable no. 220 589 00 99 32 at component B11/4 (Coolant temperature sensor).
- [M.33] 33<-->80 [M.80]
Specified values
- Voltage [20°C]: [3.36...3.48] V
- Voltage [30°C]: [2.91...2.97] V
- Voltage [40°C]: [2.40...2.45] V
- Voltage [50°C]: [1.94...1.98] V
- Voltage [60°C]: [1.53...1.57] V
- Voltage [70°C]: [1.18...1.21] V
- Voltage [80°C]: [0.92...0.93] V
- Voltage [90°C]: [0.70...0.73] V
- Voltage [100°C]: [0.54...0.56] V
- Voltage [110°C]: [0.42...0.44] V
Question: Are the measured values okay?
No
- The measured values are not o.k.
Possible cause and remedy
- Cable from component B11/4 (Coolant temperature sensor) to component N3/10 (ME-SFI control module)
- B11/4 (Coolant temperature sensor)
**End of test**
Yes
- The measured values are o.k.
**End of test**
3 Test internal resistance of component B11/4 (Coolant temperature sensor).
Test prerequisite
- The actual value is not o.k.
Test sequence
- Switch off ignition.
- Unplug the connector at component B11/4 (Coolant temperature sensor).
- Connect adapter cable no. 220 589 00 99 32 at component B11/4 (Coolant temperature sensor).
- [ B11/4] 1<-->2 [B11/4]
Specified values
- Resistor [20°C]: [2940...3240]
- Resistor [30°C]: [1900...2100]
- Resistor [40°C]: [1265...1395]
- Resistor [50°C]: [855...945]
- Resistor [60°C]: [590...650]
- Resistor [70°C]: [420...460]
- Resistor [80°C]: [305...335]
- Resistor [90°C]: [220...240]
- Resistor [100°C]: [160...180]
- Resistor [110°C]: [115...145]
Question: Are the measured values okay?
No
- The measured values are not o.k.
Possible cause and remedy
- B11/4 (Coolant temperature sensor)
**End of test**
Yes
- The measured values are o.k.
**End of test**