Trouble Diagnosis
COMBINATION METERS
Trouble Diagnosis
HOW TO PERFORM TROUBLE DIAGNOSIS
1. Confirm the symptom or customer complaint.
2. Perform preliminary check. Refer to "PRELIMINARY CHECK" .
3. According to the symptom chart, repair or replace the cause of the malfunction. Refer to Symptom Chart .
4. Does the meter operate normally? If so, GO TO 5. If not, GO TO 2.
5. Inspection End.
PRELIMINARY CHECK
1.CHECK SELF-DIAGNOSIS OPERATION OF COMBINATION METER
Perform self-diagnosis of combination meter. Refer to Self-Diagnosis Mode of Combination Meter .
Does self-diagnosis mode operate?
YES >> GO TO 2.
NO >> Check power supply and ground circuit of combination meter. Refer to Power Supply and Ground Circuit Inspection .
2.CHECK COMBINATION METER (CONSULT-III)
Select "METER/M&A" on CONSULT-III and perform self-diagnosis of combination meter. Refer to Scan Tool Testing and Procedures .
Self-diagnostic results content
No malfunction detected>> Refer to Symptom Chart .
Malfunction detected>> Refer to Scan Tool Testing and Procedures .