Operation CHARM: Car repair manuals for everyone.

Inlet Port Memory Function (REC) With Monochrome Display





INSPECTION AND ADJUSTMENT


Inlet Port Memory Function (REC)


Description





- If the ignition switch is turned to the OFF position while the REC ( ) switch is set to ON (recirculation), "Perform the memory" or "Do not perform the memory" of the REC ( ) switch ON (recirculation) condition can be selected.
- If "Perform the memory" was set, the REC ( ) switch will be ON (recirculation) when turning the ignition switch to the ON position again.
- If "Do not perform the memory" was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.

How to set
Using CONSULT-III, perform "REC MEMORY SET" in "WORK SUPPORT" of HVAC.