M/C Relay
M/C RELAY
Diagnosis Procedure
1. CHECK M/C RELAY CONTROL CIRCUIT
1.Turn power switch OFF.
2.Remove M/C relay.
3.Check the voltage between M/C relay harness connector terminals.
4.Turn power switch ON.
5.Check the voltage between M/C relay harness connector terminals.
Is the inspection result normal?
YES- GO TO 9.
NO- GO TO 2.
2. CHECK BATTERY POWER SUPPLY-I
Check the voltage between M/C relay harness connector and ground.
Is the inspection result normal?
YES- GO TO 6.
NO- GO TO 3.
3. CHECK FUSIBLE LINK
1.Remove #G fusible link.
2.Check that the fusible link is not fusing.
Is the inspection result normal?
YES- GO TO 4.
NO- Replace the fusible link after repairing the applicable circuit.
4. CHECK BATTERY POWER SUPPLY-II
Check the voltage between fusible link harness connector and ground.
Is the inspection result normal?
YES- GO TO 5.
NO- Check power supply circuit for battery power supply.
5. CHECK BATTERY POWER SUPPLY CIRCUIT-I
1.Check the continuity between M/C relay harness connector and fusible link harness connector.
2.Also check harness for short to ground and short to power.
Is the inspection result normal?
YES- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.
NO- Repair or replace error-detected parts.
6. CHECK M/C RELAY CONTROL SIGNAL CIRCUIT
1.Turn power switch OFF.
2.Disconnect VCM harness connector.
3.Check the continuity between M/C relay harness connector and VCM harness connector.
4.Also check harness for short to ground and short to power.
Is the inspection result normal?
YES- GO TO 7.
NO- Repair or replace error-detected parts.
7. CHECK VCM GROUND CIRCUIT
Check the continuity between VCM harness connector and ground.
Is the inspection result normal?
YES- GO TO 8.
NO- Repair or replace error-detected parts.
8. CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.
Is the inspection result normal?
YES- Replace VCM. Refer to "Removal and Installation" Removal And Installation.
NO- Repair or replace error-detected parts.
9. CHECK BATTERY POWER SUPPLY-III
Check the voltage between M/C relay harness connector and ground.
Is the inspection result normal?
YES- GO TO 11.
NO- GO TO 10.
10. CHECK BATTERY POWER SUPPLY CIRCUIT-II
1.Turn power switch OFF.
2.Disconnect fusible link #G.
3.Check the continuity between M/C relay harness connector and fusible link harness connector.
4.Also check harness for short to ground and short to power.
Is the inspection result normal?
YES- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.
NO- Repair or replace error-detected parts.
11. CHECK M/C RELAY
Refer to "Component Inspection (M/C Relay)" .
Is the inspection result normal?
YES- INSPECTION END
NO- Replace M/C relay.
Component Inspection (M/C Relay)
1. CHECK M/C RELAY
1.Turn power switch OFF.
2.Remove M/C relay.
3.Check the continuity between M/C relay terminals under the following conditions.
Is the inspection result normal?
YES- INSPECTION END
NO- Replace M/C relay.