Electric Compressor Insulation Resistance Check
ELECTRIC COMPRESSOR INSULATION RESISTANCE CHECK
Component Inspection
WARNING:
- Because hybrid vehicles and electric vehicles contain a high voltage battery, there is the risk of electric shock, electric leakage, or similar accidents if the high voltage component and vehicle are handled incorrectly. Be sure to follow the correct work procedures when performing inspection and maintenance.
- Be sure to remove the service plug in order to disconnect the high voltage circuits before performing inspection or maintenance of high voltage system harnesses and parts.
- To prevent the removed service plug from being connected by mistake during the procedure, always carry it in your pocket or put it in the tool box.
- Be sure to wear insulating protective equipment consisting of glove, shoes, face shield and glasses before beginning work on the high voltage system.
- Clearly identify the persons responsible for high voltage work and ensure that other persons do not touch the vehicle. When not working, cover high voltage parts with an insulating cover sheet or similar item to prevent other persons from contacting them.
- Refer to "High Voltage Precautions" High Voltage Precautions.
CAUTION:
There is the possibility of a malfunction occurring if the vehicle is changed to READY status while the service plug is removed. Therefore do not change the vehicle to READY status unless instructed to do so in the Service Manual.
1. PRECONDITIONING
WARNING:
Disconnect the high voltage. Refer to "How to Disconnect High Voltage" Service and Repair.
Check voltage in high voltage circuit. (Check that condenser are discharged.)
1.Lift up the vehicle and remove the Li-ion battery under covers. Refer to "Exploded View" Service and Repair.
2.Disconnect high voltage connector from front side of Li-ion battery. Refer to "Removal and Installation" Service and Repair.
3.Measure voltage between high voltage harness terminals.
DANGER:
Touching high voltage components without using the appropriate protective equipment will cause electrocution.
Standard: 5 V or less
CAUTION:
For voltage measurements, use a tester which can measure to 500V or higher.
- GO TO 2.
2. CHAECK ELECTRIC COMPRESSOR INSULATION RESISTANCE
1.Disconnect high voltage harness connector from electric compressor.
2.Check the insulation resistance of the electric compressor with an insulation resistance tester.
CAUTION:
- Unlike the ordinary tester, the insulation resistance tester applies 500V when measuring. If used incorrectly, there is the danger of electric shock. If used in the vehicle 12V
system, there is the danger of damage to electronic devices. Read the insulation resistance tester instruction manual carefully and be sure to work safely.
- Use 500V range of insulation resistance tester to measure insulation resistance. Wait for 30 seconds until the value becomes stable.
Is the inspection result normal?
YES- INSPECTION END
NO- Replace electric compressor. Refer to "Removal and Installation" Removal And Installation.