Inlet Port Memory Function (FRE)
SYSTEM SETTING
Inlet Port Memory Function (FRE)
DESCRIPTION
- If the ignition switch is turned to the OFF position while the intake switch is set to OFF (fresh air intake), "Perform the memory" or "Do not perform the memory" of intake switch OFF (fresh air intake) condition can be selected.
- If "Perform the memory" is set, the intake switch is OFF (fresh air intake) when turning the ignition switch to the ON position again.
- If "Do not perform the memory" is set, the air inlets is controlled automatically when turning the ignition switch to the ON position again.
HOW TO SET
With CONSULT
Perform the "FRE MEMORY SET" of HVAC work support item.
NOTE:
When the 12V battery cable is disconnected from the negative terminal or when the 12V battery voltage becomes 10 V or less, the setting of the FRE memory function may be cancelled.