Operation CHARM: Car repair manuals for everyone.

IPDM E/R




PRECAUTIONS

Precaution for Removing 12V Battery

1.Check that EVSE is not connected.
NOTE:
If EVSE is connected, the air conditioning system may be automatically activated by the timer A/C function.
2.Turn the power switch OFF ON OFF. Get out of the vehicle. Close all doors (including back door).
3.Check that the charge status indicator lamp does not blink and wait for 5 minutes or more.
NOTE:
If the battery is removed within 5 minutes after the power switch is turned OFF, plural DTCs may be detected.
4.Remove 12V battery within 1 hour after turning the power switch OFF ON OFF.
NOTE:
- The 12V battery automatic charge control may start automatically even when the power switch is in
OFF state.
- Once the power switch is turned ON OFF, the 12V battery automatic charge control does not start for approximately 1 hour.

CAUTION:
- After all doors (including back door) are closed, if a door (including back door) is opened before battery terminals are disconnected, start over from Step 1.
- After turning the power switch OFF, if "Remote A/C" is activated by user operation, stop the air conditioner and start over from Step 1.