Condenser HVAC: Service and Repair
CONDENSER
CONDENSER : Removal and Installation for Condenser
REMOVAL
1.Discharge the refrigerant. Service and Repair.
2.Remove the RH hoodledge cover.
3.Remove the front bumper fascia. Removal And Installation.
4.Disconnect the high-pressure pipe from the junction pipe.
CAUTION:
- Cap or wrap the joint of the pipe with suitable material such as vinyl tape to avoid the entry of contaminants.
5.Disconnect the high-pressure flexible hose from the junction pipe.
CAUTION:
- Cap or wrap the joint of the pipe with suitable material such as vinyl tape to avoid the entry of contaminants.
6.Disconnect the refrigerant pressure sensor connector.
7.Depress the top RH clip (A) and the top LH clip (B) to release the top condenser brackets as shown.
8.Slide the condenser up to release the condenser from the clips.
9.Remove the condenser and liquid tank assembly.
CAUTION:
- Do not damage the condenser fins
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
- Do not damage the condenser fins.
- Do not reuse O-rings.
- Apply A/C oil to the new O-rings for installation.
- When charging refrigerant, check for leaks. Checking Of Refrigerant Leaks.