Keyless Entry: Service and Repair
RH Side Of Trunk:
WHEN TO PERFORM PROGRAMING
Perform the following procedure whenever the keyless programming connector is grounded, the keyless entry receiver is replaced, the transmitter is replaced or a second transmitter is added.
PROGRAMMING PROCEDURE
1. Jumper the Keyless Programming Connector to ground (all power door locks will lock and unlock). Refer to the accompanying image for connector location.
2. Operate Transmitter by pressing a single button once (all power door locks will again lock and unlock).
3. To program for a second Portable Transmitter, operate Transmitter 2 by pressing a single button once. In order for programming to be complete, wait for the locks to fully cycle.
4. Disconnect Keyless Programming Connector Jumper after locks have finished cycling.
5. Verify that the Transmitter(s) operate Door Locks and Trunk Lid Release.