Closeout/Insulator Panel Replacement - Right
Closeout/Insulator Panel Replacement - Right
Tools Required
J 38778 Door Trim Pad Clip Remover
Removal Procedure
1. Use the J 38778 to remove the right side insulator retainers.
2. Adjust the carpet for access.
3. Disconnect the courtesy lamp from the instrument panel insulator by turning 1/4 turn counterclockwise.
4. Remove the right side insulator.
Installation Procedure
1. Position the right side insulator to the floorpan beneath the instrument panel.
2. Install the courtesy lamp to the insulator. Secure the lamp by rotating 1/4 turn clockwise.
Important: Do not block the floor heater outlet with the IP insulator.
3. Install the right side insulator retainers.