P1218
P1218
Injector Circuit, Cylinder 6 - Short to B+
Fuel Injector, cylinder 6 - Short to B+
P1230
Injector Circuit, Cylinder 6 - Short to Ground
Fuel Injector, cylinder 6 - Short to Ground
P1242
Injector Circuit, Cylinder 6 - Open
Fuel Injector, cylinder 6 - Interruption
Function
The coil of the fuel injector is supplied on one side with B+ (battery voltage) and on the other with ground via an end-stage of the ECM. For these faults the connection to ground is monitored.
Diagnostic conditions
A fault is recognized and stored in memory when the engine speed is above 80 1/min and the battery voltage is between 7.5 Volt and 17 Volt.
Wiring Diagram.
Diagnostic procedure.
Check fuel injector.
- Remove connector for injector 6
- Connect ohmmeter to pin 1 and pin 2 at injector.
- Specified value: 15- 17 ohms.
Check wiring.
- Check wiring from ECM, pin 31 to fuel injector 6, pin 2 for continuity or short circuit to B+ or ground.