Operation CHARM: Car repair manuals for everyone.

Test Point 10

Test point 10

Motor of outside air / recirculation valve

Signal implausible
Fault code 29

Diagnosis conditions

No control module fault stored.
No fault with supply voltage (5 volts).

Signal implausible

1. Check outside air / recirculation valve for smooth operation.

2. Unplug connectors A, B, C and D from the heating/air-conditioning control.

3. Unplug connector from outside air / recirculation valve drive motor.

4. Connect ohmmeter to connector D 13 and drive motor connector pin 1.
Display: < 5 Ohms

Connect ohmmeter to connector D 5 and drive motor connector pin 2.
Display: < 5 Ohms

Connect ohmmeter to connector B 17 and drive motor connector pin 3.
Display: < 5 Ohms

Connect ohmmeter to connector C 8 and drive motor connector pin 4.
Display: < 5 Ohms

Connect ohmmeter to connector A 12 and drive motor connector pin 5.
Display: < 5 Ohms

5. Check wire from connector D 13 to drive motor pin 1 for short to B+ and short to ground.

6. Check wire from connector D 5 to drive motor pin 2 for short to B+ and short to ground.

7. Check wire from connector B 17 to drive motor pin 3 for short to B+ and short to ground.

8. Check wire from connector C 8 to drive motor pin 4 for short to B+ and short to ground.

9. Check wire from connector A 12 to drive motor pin 5 for short to B+ and short to ground.