Test Point 2
Test point 2Outside temperature sensor
Open circuit
Short to ground
Fault code 21
Diagnosis conditions
No control module fault stored.
No fault with supply voltage (5 volts).
Open circuit
1. Unplug connector A from the heating/air-conditioning control.
2. Connect ohmmeter to connectors A 7 and A 12.
Display: approx. 1.2 k Ohms at 23 �C
3. Unplug connector from the outside temperature sensor.
4. Connect ohmmeter to connector A 7 and pin 1 (connector of outside temperature sensor).
Display: 0 - 5 Ohms
5. Connect ohmmeter to connector A 12 and pin 2 (connector of outside temperature sensor).
Display: 0 - 5 Ohms
6. Connect voltmeter to connector A 7 and ground.
Switch on ignition.
Display: 0 volts
If approx. 5 volts are displayed, check wiring harness for pinching and chafing damage.
Short to ground
1. Unplug connector A from the heating/air-conditioning control.
2. Connect ohmmeter to connector A 7 and ground.
Display: Infinite Ohms
If 0 - 5 Ohms is displayed, check wiring harness for pinching and chafing damage.