Test Point 3
Test point 3Interior temperature sensor
Open circuit
Short to ground
Fault code 22
Diagnosis conditions
No control module fault stored.
No fault with supply voltage (5 volts).
Outside temperature higher than - 40 �C.
Open circuit
1. Unplug connector A from the heating/air-conditioning control.
2. Connect ohmmeter to connectors A 10 and A 12.
Display: approx. 3 k Ohms at 23 �C
Note
The wires to the interior temperature sensor are routed via two additional plug connections on the heating/air-conditioning control.
3. Unplug connector from the interior temperature sensor.
4. Connect ohmmeter to connector A 10 and interior sensor connector pin 5.
Display: < 5 Ohms
5. Connect ohmmeter to connector A 12 and interior sensor connector pin 4.
Display: < 5 Ohms
6. Connect voltmeter to connector A 10 and ground.
Switch on ignition.
Display: 0 volts
If approx. 5 volts are displayed, check wiring harness for pinching and chafing damage.
Short to ground
1. Unplug connector A from the heating/air-conditioning control.
2. Connect ohmmeter to connector A 7 and ground.
Display: Infinite Ohms
If 0 - 5 Ohms is displayed, check wiring harness for pinching and chafing damage.