Operation CHARM: Car repair manuals for everyone.

P0153

P0153

Oxygen Sensor Ahead of TWC, Bank 2 - Below Limit

Diagnosis conditions
- Vehicle at operating temperature, after this 3 minutes idle speed, then approx. 30 seconds increased idle speed.

Possible fault cause
- Oxygen sensor is dynamically inert

Affected terminals
-

Diagnosis/troubleshooting

NOTE: Do not use contact spray on the connectors to oxygen sensors.






NOTE: Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter.

Oxygen sensors ahead of and after catalytic converter