800A CDR23
800A CDR23
CAN bus timeout, air-conditioning system
Diagnostic conditions
- Ignition on
- CDR23 ON
Possible cause of fault
- CAN comfort (high) - open circuit
- CAN comfort (low) - open circuit
CAN comfort is connected to the following control units:
PCM2 as of model year 2003
Instrument cluster
Air-conditioning control unit
Radio
NOTE: The plug connections of control units connected to CAN comfort are disconnected during troubleshooting. This causes additional CAN-related fault codes, e.g. 9110 DME control module to be stored in the fault memory of the instrument cluster. These fault codes should be initially ignored and should be deleted on completion of the troubleshooting.
Affected pins
CDR23 plug E, pins 1 and 2
Diagnosis/troubleshooting