Operation CHARM: Car repair manuals for everyone.

Test Point 19



Test point 19
Status lead, signal converter
Short to B+

Fault code 19
1. Pull off plug I on the alarm control module.
2. Pull off the plug on the signal converter for the transponder.
3. Voltmeter at plug I alarm control module pin 12 and ground.
Switch on ignition.
Display: 0 Volt

If battery voltage is displayed, check wiring harness for pinches and chafing damage.