Operation CHARM: Car repair manuals for everyone.

Test Point 6



Test point 6
Door lock barrel open/closed
Short to ground

Fault code 06
1. Pull off plug I on the alarm control module.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnect the plug connection X 12 (passenger's side).
4. Check the leads from the alarm control module plug I pin 35 to the door lock modules for short to ground.
- Ohmmeter at alarm control module plug I pin 35 and ground
Display: Infinity Ohms

5. Check driver's side door lock module switch contact.
- Ohmmeter at plug connection X 11 pin A4 (sleeve side) and ground.
Door lock not actuated.
Display: Infinity Ohms

Door lock actuated towards "Closed".
Display: < 5 Ohms

6. Check passenger's side door lock module switch contact.
- Ohmmeter at plug connection X 12 pin A4 (sleeve side) and ground.
Door lock not actuated.
Display: Infinity Ohms

Door lock actuated towards "Closed".
Display: < 5 Ohms

7. Check the leads from the alarm control module plug I pin 15 to the door lock modules for short to ground.
- Ohmmeter on alarm control module plug I pin 15 and ground.
Display: Infinity Ohms
8. Check driver's side door lock module switch contact.
- Ohmmeter at plug connection X 11 pin A6 (sleeve side) and ground.
Door lock not actuated.
Display: Infinity Ohms

Door lock actuated towards "Open".
Display: < 5 Ohms

9. Check passenger's side door lock module switch contact.
- Ohmmeter at plug connection X 12 pin A6 (sleeve side) and ground.
Door lock not actuated.
Display: Infinity Ohms

Door lock actuated towards "Open".
Display: < 5 Ohms