Test Point 19
TEST POINT 19
Status Lead, Signal Converter Short To B+
Fault Code 19
Fault Effect: No engine start possible
Procedure
1. Pull plug I off the alarm system control module.
2. Pull off the plug on the signal converter for the transponder.
3. Voltmeter at alarm system control module plug I, pin 4 and ground. Switch ignition on.
Display: 0 Volts
If battery voltage is displayed, check the wiring harness for pinches and chafing damage.