P0480
P0480
494 Fan output stage 1 - open circuit
Diagnosis conditions
- Engine running
- Battery voltage greater than 7 V
- Intake air temperature greater than 9 °C
- Air conditioning switched on and off once
NOTE: The triggering wire for relays stage 1, terminal 85, is monitored
Possible fault cause
- Open circuit
- Relay faulty
- DME control module faulty
Affected terminals
Terminal IV/4
Diagnosis/troubleshooting
Part 1:
Part 2:
494 Fan output stage 1 - below limit
Diagnosis conditions
- Engine running
- Battery voltage greater than 7 V
- Intake air temperature greater than 9 °C
- Air conditioning switched on and off once
NOTE: The triggering wire for relays stage 1, terminal 85, is monitored
Possible fault cause
- Short circuit to ground
- Relay faulty
- DME control module faulty
Affected terminals
Terminal IV/4
Diagnosis/troubleshooting
494 Fan output stage 1 - above limit
Diagnosis conditions
- Engine running
- Battery voltage greater than 7 V
- Intake air temperature greater than 9 °C
- Air conditioning switched on and off once
NOTE: The triggering wire for relays stage 1, terminal 85, is monitored
Possible fault cause
- Short circuit to B+
- Relay faulty
- DME control module faulty
Affected terminals
Terminal IV/4
Diagnosis/troubleshooting