P0482
P0482
591 Fan output stage 3 - open circuit
Diagnosis conditions
- Engine running
- Battery voltage greater than 7 V
- Engine temperature greater than 108 °C
- Vehicle speed greater than 25 km/h (15 mph)
- Engine speed more than 1000 rpm
NOTE: The triggering wire for relays stage 3, terminal 85, is monitored.
Possible fault cause
- Open circuit
- Relay faulty
- DME control module faulty
Affected terminals
Terminal IV/31
Diagnosis/troubleshooting
Part 1:
Part 2:
591 Fan output stage 3 - below limit
Diagnosis conditions
- Engine running
- Battery voltage greater than 7 V
- Engine temperature greater than 108 °C
- Vehicle speed greater than 25 km/h (15 mph)
- Engine speed more than 1000 rpm
NOTE: The triggering wire for relays stage 3, terminal 85, is monitored.
Possible fault cause
- Short circuit to ground
- Relay faulty
- DME control module faulty
Affected terminals
Terminal IV/31
Diagnosis/troubleshooting
591 Fan output stage 3 - above limit
Diagnosis conditions
- Engine running
- Battery voltage greater than 7 V
- Engine temperature greater than 108 °C
- Vehicle speed greater than 25 km/h (15 mph)
- Engine speed more than 1000 rpm
NOTE: The triggering wire for relays stage 3, terminal 85, is monitored.
Possible fault cause
- Short circuit to B+
- Relay faulty
- DME control module faulty
Affected terminals
Terminal IV/31
Diagnosis/troubleshooting